InfraStruxure Data Centers Mean Business

Learn more about integrated power, cooling, racks, management and services:

View The Next Generation Of InfraStruxure™

InfraStruxure™ is the scalable and adaptable data center IT room architecture that dramatically reduces time and complexity from concept and design through installation. Power, cooling, racks, security and management components are conceived and tested as part of an integrated system which is evident in the aesthetics, functionality and ease of management software integration. Taking a broad system view enables full realization of the benefits of going fast, going dense and going green while ensuring your critical availability targets are met. An open system, InfraStruxure™ is the proven “on demand” architecture for data center IT rooms small and large, delivering high availability and real energy savings whether deployed on its own, in a zone, or in incremental steps.

This new generation of InfraStruxure™ delivers:

  • Higher performance – 25 percent increase in power and cooling capacity, 15 percent smaller footprint
  • More scalability – as big as you want to go
  • Faster and easier planning through operations – automated planning and design tools with open & integrated management and operations software
  • More innovation and leadership – from the worlds leader in data center physical infrastructure all while reducing cost!

To learn more about integrated power and cooling,  please contact Waite Ave at w.ave@apcdistributors.com or 281-825-9790.

Don’s Corner: “Understanding The Average Return On Investment (ROI) After Completion Of A Data Center Assessment”

Posted by on December 7, 2010  |  No Comments

Don Melchert, Critical Facility Specialist

Understanding The Average ROI After Completion Of A CFEP

The Cost of Downtime is Exponential

Every critical facility experiences growing pains throughout its lifespan. Unexpected equipment failures, such as a UPS or HVAC system, can halt productivity resulting in costs that can be hidden, yet are exponential in nature. For instance, a failed UPS must be returned to normal operation as soon as possible in order to continue critical operations. In our competitive market, downtime is not an option. Without expensive, quick response service contracts, we are at the mercy of our vendors when it comes to emergency after-hours unscheduled maintenance. The service technicians will be on site at an increased hourly rate, of course, but what about the premium placed on the parts and materials needed to complete the repair?

Exploring the scenario further, those hidden, exponential costs come to light with a fury. The combination of an after hours (emergency) service bill plus parts is already expensive enough, but, in order to calculate the total cost, one must consider the additional cost of manpower from the staff that will be on-site and the additional resources used to support the corrective maintenance action. Let’s assume that the failure scenario stemmed from a generator failure during a power outage, and, during this outage, some of the UPS batteries failed. An all too common scenario and one that, unfortunately, many an I.T. or Facilities Manager has found themselves at the mercy of. To start from the top, lighting will be needed in the repair location, but what about the staff member’s office? …and the hallways leading to it? …and possibly the break room? …and eventually the restroom? What additional costs might be incurred if an accident or injury occurs during the maintenance action? Don’t forget, even after all of the repairs have been performed and the system returned to normal, additional support resources will be used to make the invoice payments to the service provider.

From the example above, it’s easy to see that calculating the total cost of a service interruption includes a lot more than just the temporary service interruption and what’s on the parts and labor invoice. If a critical facility can find and eliminate just one of the factors that can cause a critical systems failure, then conversely, the savings can be exponential as well!

Our Difference is Value

The majority of critical facility inspections and evaluations are performed while focusing on only the inner workings of the data center. The goal, for most companies performing the evaluations, is to show how much energy making any changes or corrections has made based in what was found during the inspection. Their entire approach is to locate key points in the data center where energy is being wasted or resources are being utilized inefficiently. However, the ability of a critical facility to remain online 100% of the time is the result of all of its Network Critical Physical Infrastructure components working together efficiently, not just what occurs solely in the data center.

A Critical Facility Energy Profile (CFEP) from UNS is different in that the evaluation is holistic, right from the start. Without interrupting the operational capabilities of the facility and its staff, a CFEP inspection actually begins from the moment the Critical Facility Specialist arrives at the site. If permitted, the entire facility and its NCPI components, from infrastructure to security, are inspected and each finding is taken into consideration when establishing an efficiency benchmark. Upon completion, the CFEP Report Card showcases any items where efficiency can be improved and suggests corrective strategies that will immediately reduce costs for a business across multiple cost centers. The total cost savings is dynamic, as savings in one area increase savings in another and another. In the end, it’s the bottom line that’s improved, not just one section of the business.

Seeing is Believing

WARNING: Any dollar value quoted for the ROI after performance of a CFEP will be false (low), as there is not sufficient data to accurately determine future savings gained from making a particular increase in efficiency. However, in this rare occasion, having an inaccurate prediction is definitely an error in your favor! Although the CFEP is holistic in nature, if we dissect just one section, such as a decrease in energy consumption gained by improving air conditioning efficiency, then we can show the savings in dollars for just that section.

As an example, we’ll use a critical facility in Indiana, with a total load of 8000kW consumed per hour at the current average energy cost in Indiana of $.0713 per kWh. If the facility is operating at the nation’s average of 50% efficiency and a PUE of 2.0, then their current annual energy costs is approximately $ 4,996,704 USD.

During a CFEP, it was determined that the orientation of the data racks in interfering with the airflow from the CRAC units, effectively forcing them to run on high at all times. The facility took action, implemented the recommendations from the CFEP and was able to completely eliminate one of their CRAC units and decrease the fan speeds of the remaining systems. If this facility can become just 1% more efficient in their total energy consumption, the cost savings is significant. Their total load has now dropped to 7600kW with a PUE of 1.90. Assuming the cost of energy remains constant, their annual energy cost has now dropped to $4, 746, 869 USD. From making just one change, to only one aspect of their NCPI, resulting in a meager 1% increase in efficiency, they now have a savings of $249,835 USD in the first year, and greater savings in years to come.

Again, although this example is impressive, it’s still very conservative and technically, it’s inaccurately low. The additional cost of savings associated with the elimination of one CRAC unit, including preventative maintenance contracts, consumable parts and all of the reduced man hours necessary to keep it operating at 100% would need to be added to the savings above in order to accurately show the full ROI for just one portion of a CFEP!

Don Melchert
Critical Facilities Specialist

Universal Networking Services, LLC Launches “Breakfast and Learn” Educational Series for Data Center Professionals

Posted by on August 4, 2010  |  No Comments

Denver, Colorado, July, 21, 2010: Universal Networking Services, LLC (UNS, LLC), a leading provider of mission-critical power and cooling infrastructure products and services today announced the launch of “Breakfast and Learn” Educational Series starting August 18th and 19th in Denver, Colorado

Waite Ave, Managing Partner for UNS,  states “Today’s IT departments face complex challenges that demand forward looking IT solutions. Corporate CIOs, Facility Mangers, and IT Managers are facing a real crisis when it comes to cooling their critical facilities.  Not least among these challenges is the delicate balancing act of ensuring reliability without energy cost getting out of control.  High-density deployments are creating cooling challenges that cannot be solved by the current design practice. Data center cooling systems must be more adaptable to changing requirements.  How cooling is deployed into today’s data centers has a major effect on operating costs.  Most vendors are not addressing the pressing problems created by the current design practices or equipment.  The “Breakfast and Learn” series provides educational opportunities and showcases the latest in technologies for data center power and cooling .  Education that will lay the critical foundation to run an efficient data center.   At UNS, LLC our philosophy is to offer the data center professional the tools and resources to lower their Total Cost of Ownership (TCO) and maximize efficiencies offered by the advancements in today’s data center architecture.  We are very excited to team with American Power Conversion (APC) to empower the Denver data center community to find real-time solutions to their unique challenges.”

About “Breakfast and Learn” Series:

The “Breakfast and Learn” series offers the Denver data center community multiple opportunities to learn from their peers, share experiences, and expand industry knowledge.  Educational sessions will be offered quarterly starting with the following sessions scheduled for August 18th and 19th respectively:

“RIGHT-SIZING VERSUS OVER-SIZING:  EFFICIENCY IN THE DATA CENTER

“IS PERIMETER COOLING DEAD?”

About Universal Networking Services, LLC (Sponsor):

UNS, LLC specializes in mission-critical power and cooling solutions for wiring closets, server rooms, and data centers.  UNS, LLC provides product acquisition, design/ engineering, installation management and maintenance services.

About American Power Conversion (Co-Sponsor):

APC is considered a global leader in data center physical infrastructure (DCPI) solutions.  APC sets the standard in its industry for quality, innovation and support.

UNS, LLC and APC will conduct the “Breakfast and Learn” series at APC’s Demo Data Center located at 6350 W. 54th Avenue, Arvada, CO 8002.  To RSVP please contact UNS.

To learn more about the “Breakfast and Learn” Educational series please contact Waite Ave at w.ave@apcdistributors.com or call 281-825-9790.