Posts Tagged Indirect Evaporative Cooler (IEC)

APC by Schneider Electric Announces EcoBreeze™, the First Air Economizer Cooling Solution that Keeps Outside Air Out of the Data Center

Posted by on January 16, 2011  |  No Comments

APC by Schneider Electric’s modular indirect evaporative and air-to-air heat exchanger cooling solution is able to automatically switch between two forms of cooling to meet all of the cooling and energy efficiency requirements facing today’s data centers

LONDON, United Kingdom, November 9, 2010 — APC by Schneider Electric, a global leader in integrated critical power and cooling services, today announced the EcoBreeze™, a modular indirect evaporative and air-to-air heat exchanger cooling solution. The EcoBreeze has the unique ability to switch automatically between air-to-air and indirect evaporative heat exchange to consistently provide cooling to data centers in the most efficient way. The design of the EcoBreeze is able to reduce energy consumption by leveraging temperature differences between outside ambient air compared to IT return air to provide economized cooling to the data center. The EcoBreeze meets ASHRAE 90.1/TC 9.9 requirements for efficiency and economization with multiple frame sizes with varying voltages and phases to address any data center’s cooling needs.

As data centers are constantly expanding and local energy companies place heavy restrictions on a data center’s ability to pull more power from the grid, there is an urgent need to reduce power consumption through energy efficiency and economization. The EcoBreeze addresses the needs of today’s data center’s by implementing multiple forms of economization into each module. The unit, located outside the perimeter of the data center, takes advantage of localized climates and can automatically switch between two forms of economized cooling;

·         Air-to-air heat exchange – Brings in hot IT air in from the data center through the modules EC (Electronically Commutated) fans which is then passed through internal channels of the Indirect Evaporative Cooler (IEC). After the IT air is cooled it leaves the IEC and passes through a cooling coil and returned to the data center.

·         Indirect evaporative heat exchange – When ambient temperatures can’t support a air-to-air heat exchange cooling is done through indirect evaporative cooling which removes heat from the IT air by evaporating water on the outside of the heat exchanger channels. The EcoBreeze is the first solution on the market which prevents the outside air from coming in contact with the data center air, regardless of which cooling mode is used (air-to air or indirect evaporative).

The EcoBreeze has a proportional R410a refrigerant system as well as an onboard water treatment system which eliminates the need for chemical water treatment. This feature addresses environmental concerns associated with some refrigerant or water based systems.  Both of the economization cooling strategies employed by the EcoBreeze maximize localized climate conditions to ensure the most efficient and effective form of cooling throughout the year.

The EcoBreeze will be announced at DatacenterDynamics London which will be held at the Lancaster Hotel, London, November 9 and 10, 2010. The EcoBreeze will be available for purchase in 2011.